Perfect International Instruments Co., Ltd

Perfect International Instruments Co., Ltd Not Guess , But Test !

Manufacturer from China
Verified Supplier
8 Years
Home / Products / Adhesion Testing Machine /

Initial Viscosity Rolling Ball Tack Tester Tape Adhesive Stickiness Testing Machine

Contact Now
Perfect International Instruments Co., Ltd
Visit Website
City:dongguan
Province/State:guangdong
Country/Region:china
Contact Person:MrMichael Chan
Contact Now

Initial Viscosity Rolling Ball Tack Tester Tape Adhesive Stickiness Testing Machine

Ask Latest Price
Video Channel
Brand Name :PERFECT
Model Number :PT-6032
Certification :ISO9001
Place of Origin :China
MOQ :1 set
Price :Negotiation
Payment Terms :T/T, L/C, Western Union
Supply Ability :800 sets per month
Delivery Time :3 working days afer confirming order
Packaging Details :Neutral packing or as customers's request
Model No :PT-6032
Standard :GB/4852, PSTC 7
Tilt angle :22°
Item :Tape Initial Tackness Tester
Machine Dimension :20*6*7cm
Slope Length :6.5 Inch
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Initial Viscosity Testing Apparatus Tape Adhesive Tackness Testing Machine

Purpose of Adhesive Testing Machine:

Tape Adhesive Tackness Testing Machine is takes a steel ball rolling on adhesive tape by rolling distance to determine the merits of tape tack.

Specifications:

Standard GB/4852, PSTC 7
Item Name Tape Adhesive Tackness Testing Machine

Tilt angle

22°

Rolling Ball Dia

(7/16”, No.14)

Machine Dimension

200mm*60mm*70mm

Apparatus Structure Picture:

Initial Viscosity Rolling Ball Tack Tester Tape Adhesive Stickiness Testing Machine

Operation Steps:

  1. Clean up chute and grounder on the tester by GB/T 4852-2002 specified ways,and after that you cannot touch them anymore.
  2. Fix test piece on hard and horizontal test board(glass pane,metal plate,plank,plastic plate and so on).Donot let test piece bulge,wrinkle or warping.
  3. As the picture show,fix chute and grounder on test plate which has installed test piece flatly.
  4. Put the grounder on specified initial position, let it roll down freely along the chute.
  5. Measure the length from the place where grounder stop to the end of the chute.
  6. Carry on the next initial adhesion testing.